Aranet Andur T/RH Test Andur T: -40°C kuni 60°CRH: 0% kuni 100% IP42 868 MHz

Tootekood: TDSPT001 (EU) TOOTETÜÜP: IoT SARI: Aranet Mõõdud: 115x44x25 mm/ 4.5×1.7×1 in KAAL: 65g / 2.3oz
Allalaadimised

Hind: 96,00 €

Aranet wireless temperature and relative humidity sensors have exceptionally low energy consumption that allows the sensors to function up to 10 years without replacing the battery. Aranet Sensors are extremely durable and can be placed in an open environment as well as indoors or humid locations

Otsas

Kategooriad: ,
KIRJELDUS
Aranet wireless temperature and relative humidity sensors have exceptionally low energy consumption that allows the sensors to function up to 10 years without replacing the battery. Aranet Sensors are extremely durable and can be placed in an open environment as well as indoors or humid locations.

  • Sensors are compatible only with Aranet base stations
  • Measures: temperature (-40°C to 60°C/ -40°F to 140 °F)
  • Measures: Relative humidity (0% to 100%)
  • Line-of-Sight range: up to 3 km/ 1.9mi
  • Operating environment: indoor and outdoor use
  • Transmitter power: 14 dBm
  • Data Transmission: 1, 2, 5, 10 minutes
  • Battery life: up to 10 years
  • Protection class: IP42
  • Dimensions: 115x44x25 mm/ 4.5×1.7×1 in
IP CLASS 42
UP TO 10 YEAR BATTERY LIFE
TEMPERATURE, RELATIVE HUMIDITY MONITORING
AT LEAST 3KM LINE-OF-SIGHT RANGE

Aranet T/RH sensor Datasheet

Aranet T/RH sensor
Measurements Temperature
Relative Humidity
Line of Sight Range 3km/1.9mi
Operating environment Indoor and Outdoor use
Transmitter power 14 dBm
Frequency Depends on base station instructions
Measurement range Temperature -40°C to 60°C/-40°F to 140°F
Relative Humidity 0% to 100%
Temperature measurement accuracy -10°C to 60°C/14°F to 140°F 0.4°C/0.72°F
-20°C to -10°C/-4°F to 14°F 0.6°C/1.08°F
-40°C to -20°C/-40°F to 14°F 0.9°C/1.62°F
Relative Humidity measurement accuracy 0 to 80% @ 30°C/86°F 4%RH
80% to 95% @ 30°C/86°F 6%RH
Response time Τ63% 4 minutes at 1 m/s airflow
Data Transmission 1, 2, 5, 10 minutes**
Data Protection Data encryption
Power options 2 AAA Alkaline batteries (Zn/Mn02)
2 AAA Lithium batteries (Li/FeS2)
Battery life @20°C/68°F Up to 7 years with Alkaline batteries
Up to 10 years with Lithium batteries
Operating temperature -20°C to 55°C/-4°F to 131°F with Alkaline batteries
-40°C to 60°C/ -40°F to 140°F with Lithium batteries
Operating humidity 0% to 100% non-condensing*
Dimensions 115x44x25 mm/ 4.5×1.7×1 in
Weight 65g/ 2.3oz with Alkaline batteries
57g /2.3ozwith Lithium batteries
Construction ASA Plastic
Protection class IP42
Compatible base stations Aranet PRO, Aranet MINI
Marking CE, FCC, IC
Included 2 AAA Alkaline batteries, string

Aplications:

STORAGE FACILITIES
AGRICULTURE 
FOOD MANUFACTURING 
MUSEUMS/EXHIBITION HALLS
BUILDING MANAGEMENT
FOODSERVICE INDUSTRIES
DATA CENTERS
PHARMA INDUSTRY

Aranet wireless temperature and relative humidity sensors have exceptionally low energy consumption that allows the sensors to function up to 10 years without replacing the battery. Aranet Sensors are extremely durable and can be placed in an open environment as well as indoors or humid locations.

  • Sensors are compatible only with Aranet base stations
  • Measures: temperature (-40°C to 60°C/ -40°F to 140 °F)
  • Measures: Relative humidity (0% to 100%)
  • Line-of-Sight range: up to 3 km/ 1.9mi
  • Operating environment: indoor and outdoor use
  • Transmitter power: 14 dBm
  • Data Transmission: 1, 2, 5, 10 minutes
  • Battery life: up to 10 years
  • Protection class: IP42
  • Dimensions: 115x44x25 mm/ 4.5×1.7×1 in
IP CLASS 42
UP TO 10 YEAR BATTERY LIFE
TEMPERATURE, RELATIVE HUMIDITY MONITORING
AT LEAST 3KM LINE-OF-SIGHT RANGE

Aranet T/RH sensor Datasheet

Aranet T/RH sensor
Measurements Temperature
Relative Humidity
Line of Sight Range 3km/1.9mi
Operating environment Indoor and Outdoor use
Transmitter power 14 dBm
Frequency Depends on base station instructions
Measurement range Temperature -40°C to 60°C/-40°F to 140°F
Relative Humidity 0% to 100%
Temperature measurement accuracy -10°C to 60°C/14°F to 140°F 0.4°C/0.72°F
-20°C to -10°C/-4°F to 14°F 0.6°C/1.08°F
-40°C to -20°C/-40°F to 14°F 0.9°C/1.62°F
Relative Humidity measurement accuracy 0 to 80% @ 30°C/86°F 4%RH
80% to 95% @ 30°C/86°F 6%RH
Response time Τ63%
4 minutes at 1 m/s airflow
Data Transmission 1, 2, 5, 10 minutes**
Data Protection Data encryption
Power options 2 AAA Alkaline batteries (Zn/Mn02)
2 AAA Lithium batteries (Li/FeS2)
Battery life @20°C/68°F Up to 7 years with Alkaline batteries
Up to 10 years with Lithium batteries
Operating temperature -20°C to 55°C/-4°F to 131°F with Alkaline batteries
-40°C to 60°C/ -40°F to 140°F with Lithium batteries
Operating humidity 0% to 100% non-condensing*
Dimensions 115x44x25 mm/ 4.5×1.7×1 in
Weight 65g/ 2.3oz with Alkaline batteries
57g /2.3ozwith Lithium batteries
Construction ASA Plastic
Protection class IP42
Compatible base stations
Aranet PRO, Aranet MINI
Marking CE, FCC, IC
Included 2 AAA Alkaline batteries, string

Aplications:

STORAGE FACILITIES
AGRICULTURE 
FOOD MANUFACTURING 
MUSEUMS/EXHIBITION HALLS
BUILDING MANAGEMENT
FOODSERVICE INDUSTRIES
DATA CENTERS
PHARMA INDUSTRY